Monday 19 January 2015

Best Fire Fighting System In Kerala




Best Fire Fighting System


Stored Pressure Type

Stored Pressure Extinguishers are designed for the protection of light, ordinary and extra high hazards. 
These compact extinguishers are suited for both industrial and commercial fire protection needs. 
Typical applications include:
Light manufacturing, warehouses, restaurants, office buildings, shop areas, auto repair shops, paint process areas, welding areas, machinery, residential apartments, parking garages, aircraft servicing areas, material handling vehicles.

Features:

Ø       Manufacturing standard is BSEN3
Ø       Ready for instant use.
Ø       Highly effective on class A, B, C & Electrical fires.
Ø       Heavy duty steel cylinder
Ø       Made of special CRCA sheet with Argon/CO2 welding process.
Ø       Simple operation and maintenance



Powder Skid Unit

Application

Ø       Petroleum / Petrochemical:      Loading Racks, Refinery Processing Equipment, Product                      Transfer And Processing Areas

Ø       Marine: Tanker Decks, Machinery Spaces, Loading Docks

Ø      Manufacturing : Industrial Operations (paint spray booths, dip and quench tanks), Warehouses,            Steel Mills, Paint And Solvent Mixing Areas, Machinery Lubricating Systems, Flammable                  Liquid Storage Areas

Ø      Utilities: Transformers, Generators, Turbines, Control Equipment, Fuel Storage Areas

Ø      Natural Gas:     LNG Tankers, Natural Gas Plants, Process Piping, Vaporizers, Compressors,              Liquification Plants, Sump Areas, Truck Loading Areas.

Features:

Ø      Custom-built to meet specific client requirements.
Ø      Capacity up to 1000kg.
Ø      Provides ideal protection for high risk area where there is high chances of fire.
Ø      The system can be activated remotely or by manually opening the nitrogen cylinder valve.
Ø      Discharge can be via handline nozzles or monitors to suite site requirements.
         Special marine paint available for offshore or coastline applications.







Ø      Natural Gas:     LNG Tankers, Natural Gas Plants, Process Piping, Vaporizers, Compressors,              Liquification Plants, Sump Areas, Truck Loading Areas.

Features:

Ø      Custom-built to meet specific client requirements.
Ø      Capacity up to 1000kg.
Ø      Provides ideal protection for high risk area where there is high chances of fire.
Ø      The system can be activated remotely or by manually opening the nitrogen cylinder valve.
Ø      Discharge can be via handline nozzles or monitors to suite site requirements.
         Special marine paint available for offshore or coastline applications.



Powder Cart Unit



Application

Ø      Unit with metal dry powder for class D fire of magnesium, sodium etc.
Ø      Unit with monnex dry powder.
Ø      Special rear lights.

Features:

Ø     Robust design.
Ø     High efficiency in extinguishing power.
Ø     Ideal protection for high risk installations such as military bases, large warehouses, fuel depots,          airports etc.
Ø     2 x 27 liters of compressed nitrogen cylinders, with charging pressure of approx 200 bars.


Saturday 17 January 2015

Best Fire Alarm Systems In India




Dutch Tech Group we are committed to reduce the worldwide burden of fire and other hazards on the quality of life of the communities we serve by providing Dutch Tech SAT Safety Security Surveillance (DTSATSSS)











Dutch tech group Fire Alarm System detects and notifies early signs of fire even before it starts. It can help you reduce the risk of injury or death to employees and visitors as well as minimise damage to your property and disruption to your operations.







 Our 24 hour monitoring ensures your business is watched over at all times, even during non-business hours.






Tuesday 9 December 2014

Extended Coverage Sprinklers

Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra hazard occupancies. Sprinklers are designed to protect ordinary hazard occupancies with a maximum coverage area.the standard distribution of sprinkler heads will not provide enough coverage. In these cases, extended coverage sprinkler heads can be installed to increase the spacing between heads. Extended coverage sprinklers have a water distribution radius of a little over 10 feet, so they can be spaced approximately 20 feet apart.                                                                   

Criteria for the location of sprinkler heads. First, sprinklers must be located so they are within the hot-gas layer that develops near the ceiling during a fire because activation occurs when the sprinkler head reaches a certain temperature. Second, they must be located so that the water that is discharged from the sprinkler is not disrupted or affected by construction elements such as beams, trusses, or soffits.The extralarge orifice produces the flows required to meet Light and Ordinary Hazard density requirements at lower pressures than standard orifice or large orifice sprinklers.The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards.During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern.
                                                             

Two Main Criteria For Location Of Sprinkler Heads

  • Because fire sprinklers are heat activated, sprinkler heads must be located high up on or near the ceiling.
  • Sprinkler heads must be unobstructed to provide maximum flow to the areas that need it. This means they cannot be blocked by beams, trusses, soffits, or any other elements of your building’s construction.                   

Tuesday 2 December 2014

Digital Intelligent System

An Digital Intelligent Systems is a machine with an embedded, Internet-connected computer that has the capacity to gather and analyze data and communicate with other systems.  As this ongoing trend continues, many foresee a scenario known as the Internet of Things (IoT), in which objects, animals and people can all be provided with unique identifiers and the ability to automatically transfer data over a network without requiring human-to-human or human-to-computer interaction. digital Intelligent systems that can analyze digital information and sensory data, draw the right conclusions, and act on them in the digital or physical world are of rapidly growing importance.intelligent fire alarm system shall comply with requirements of  Standard for protected premises signaling systems. The system shall be electrically supervised and monitor the integrity of all conductors.Fire Finder system operates with high-performance devices and systems.
                                                                     
 Fire Finder system Includes:

• Notification devices
• FirePrint intelligent fire detectors
• Special hazards extinguishing systems
• Integrated digital emergency voice evacuation system
• Multiple FireFinder Networking System (compatible with MXL)
• Network Command and Control (NCC) and Wide Area Network Systems (NCCWAN)
                                                          

Thursday 20 November 2014

Residential Sprinklers

Residential fire sprinklers in all new one-and two-family dwellings and townhouse construc­tion statewide. For many years, installation of fire sprinkler systems has only been required in office buildings and multi-family dwellings. These sprinkler systems are proven to save lives and extinguish fires. Despite the statistics, home fire sprinklers have yet to become code-mandated in new-home construction, and few homeowners who have the option choose to include this life-saving investment in their home.A residential sprinkler system is designed to use just enough water to control the fire. Typically one sprinkler head discharges 38-40 litres of water a minute compared to a firefighter's hose at 1000+ litres a minute. This minimises water damage and a room protected by sprinklers can often be back in use within a couple of hours.Residential fire sprinklers are not expensive.The sprinklers themselves are small, neat and blend in with the decor. The heads are connected through a system of pipes to the water mains or an alternative secure source of water. Most rooms require only two sprinkler heads to afford complete protection. Residential Sprinklers for Fire Protection Service . fire sprinklers be included a standard feature in all new homes. 
                                                                  


Multiple Occupation Of Residential sprinklers Includes:

Apartments
Dormitories
Blocks of flats
Nursing homes
Boarding houses
Residential homes
Aged persons homes
Residential rehabilitation accommodation
                                                         

Sunday 16 November 2014

Deluge Fixed Fire Protection System

Deluge system is designed to protect high hazard areas containing a severe fuel hazard with a high heat release rate by bringing a large number of open sprayers into action simultaneously in the event of a fire. Deluge valve system comprises of a control valve, a sprinkler operated detection system and a dedicated water supply system. For small or confined high hazard risk areas, Multiple Controls can be used instead of sprinklers. Deluge system is similar to a pre-action system except the sprinkler heads are open and the pipe is not pressurized with air. Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system. Deluge systems are used in the protection of large Aircraft Hangers as one primary means of fire protection.                                                    

Deluge fire sprinkler systems are used where special hazards create a concern for rapid fire spread. These systems provide a simultaneous application of water over the entire hazard to ensure fast and effective suppression of the fire. Water is not present in the piping until the deluge valve is tripped, reducing the risk of leakage or damage to unseen areas of the building. deluge fire sprinkler  system is to quickly wet down an entire hazard area to prevent a fire from spreading. They are usually used in facilities that contain hazardous materials such as: flammable liquids, chemicals, and explosives.Deluge pipe fire sprinkler systems feature open-type sprinkler heads attached to a dry pipe that is connected to a main water supply. Using an innovative detection system that recognizes smoke or heat, this fire suppression installation activates a valve that releases water to all sprinklers.                                      
Applications Of Deluge System

Libraries
Archives
Aircraft Hangars
Computer Rooms
Refrigerated Areas
Flammable Liquid Handling
Storage Areas for Valuable Artifacts
High-Hazard Installations Using Water as Extinguishing Agent                     

Wednesday 12 November 2014

End Suction Fire Pumps

End suction fire pumps are specifically designed to significantly reduce fire pump space requirements. Available with either an electric motor or diesel engine driver, the pumps can address a wide range of fire pump applications. Aurora’s end suction fire pumps feature a back pullout design for easy disassembly and maintenance.End Suction Fire Pump deploy a heavy-duty bearing frame to provide long and reliable service in an over-hung impeller design. The end-suction format eliminates the design layout constraints imposed by horizontal split-case pump configurations. Available at a very economical market rates.The approval demonstrates that an independent assessment has been made of the Fire Pump Manufacturer's packages and processes and that they conform to industry standards.End suction pumps are the most common configuration for centrifugal pumps, and the least expensive configuration in many cases. A huge variation of sizes, materials of construction, and designs are offered by manufacturers to handle everything from water at ambient temperature to high pressure and high temperature viscous oils, abrasive slurries, and corrosive chemicals.The end suction pump is a suction pressure pump with its suction nozzle on the opposite side of the casing from the stuffing box, with the face of the suction nozzle perpendicular to the longitudinal axis of the shaft.                               
                          

End Suction Fire Pumps are available in two configurations frame mounted or close-coupled, which can be flanged or threaded. These pumps ably bring Patterson’s rugged performance and reliability to existing applications or new installations.Fire Pump approvals are of course essential for the peace of mind of those that build, operate or use buildings.end suction centrifugal fire pumps with appropriate fittings for providing water supply to fire protection systems in buildings, plants and yards.                 


Features and Benefits

Frame-Mounted Design
Small Footprint Ideal for Retrofit
Self-venting design eliminates the need for automatic air release valve.
Hydraulically balanced impeller extends bearing life and assures smoother operation.
Available in electric motor or diesel engine driven configuration.
Rear pullout design supplied as standard with spacer coupling.
Top centerline discharge with foot supported casing.

           
Applications

Plumbing
Pressure Boosting
Industrial
Water Utility
Wastewater
Agriculture